| SPECIFICATIONS: SatisfiesSANS 1777 (2004) | ||
| SANS 1777:2004 | Requirement | Tested |
| General | ||
| Operating ambient temperature | -15C to +60C | |
| Orientation | Omni-directional | |
| Environmental stability | Resistance to ageing | UV stabilised? |
| Mechanical Strength | ||
| PECU shape | Conical or spherical | Conical |
| Base connections | NEMA or 20mm screw | NEMA |
| Degree of protection | IP65 | IP65 |
| Impact strength | > 0.5 Nm | |
| Electrical | ||
| Mains voltage | 230Vrms +/- 10% | 230Vrms +/- 10% |
| Insulation resistance | 500Vdc | |
| Dielectric strength | ||
| Surge arrestor | required | |
| Contact rating | 1800VA for 1000 cycles | |
| Insulation system | Class E (1200C) | |
| PECU failure mode | ON or closed | Failure in on position |
| Creepage and clearances | SANS 60598-1 Sect.11 | |
| Photometric performance | ||
| Switch on level | 60 lux +/- 12 lux | |
| Switch off level | < 1.5 x switch on level | |
| Switching delay | >15 seconds | |
| Durability after 1000 cycles | Within 5% | |
| Durability and marking | ||
| 15s with water and hexane | No curing or peeling | |
| Resistance to heat | ||
| Base insulating material | SANS 60598-1sect.13.2.1 | |
| Resistance to heat and fire | ||
| Base material shall resist fire | SANS 60598-1sect.13.3.2 | |