Emergency Control Gear - Standard Range

TLX Range
Standard emergency control unit for fluorescent lamps
The TLX range of emergency control units cover all axial fluorescent lamps as well as four pin compact types from 6 to 65 Watts. The following versions provide an emergency lighting duration of either one or three hours:














The units comply with BS EN 60598-2-22, BS EN 60924 and SABS 1464: Part 22. Either maintained or non-maintained mode can be used. A safety start circuit is provided that prevents emergency operation until mains is connected. This enables installation without disconnecting or depleting the batteries. A red light indicates that the batteries are being charged. The unit is housed in a high quality glass sphere reinforced polyamide polymer. This material has excellent high heat resistance and impact strength properties. The emergency light output is sufficient to satisfy most escape route and anti-panic area lighting requirements. The unit can be used with conventional switch start, electronic or dimming ballasts.

Note 1: The emergency lighting duration and light output may vary due to ambient temperature, cell type and lamp manufacturer.
Note 2: The unit may be provided for operation from 110Vac.


Units also available with a photocell option.
The standard TLX5/1hr/E/T emergency controller has been re-engineered into a low profile “Slim-Line” unit. The new configuration allows the unit to be easily housed in T5 bulkheads where its predecessor could not be accommodated but still retains all the features of its predecessor. The compact size of this controller is becoming increasingly important to customers who wish to use sleeker, low profile fixtures. The controller measures W=30mm x H = 30mm x L= 250mm

Although the TLX5/1/E/T-Slim controller is still capable of driving all linear fluorescent lamps as well as four pin compact types from 6 to 80 Watts the “Slim” version has specifically been designed to be accommodated in T5 low profile bulkheads and is also capable of driving T5 lamps from 8 to 54W.

The emergency light output is sufficient to satisfy most escape route and anti-panic area lighting requirements.

The unit can be used with conventional switch start, electronic or dimming ballasts.

The units comply with BS EN 60598-2-22, BS EN 60924 and SABS 1464: Part 22.

Either maintained or non-maintained mode can be used. A safety start circuit is provided that prevents emergency operation until mains is connected. This enables installation without disconnecting or depleting the batteries. A battery charge indicator is incorporated.

The unit is currently housed in an alu-zinc housing.

Poke-in wire trap connectors have been added to this design which greatly simplifies connection wiring.

A splice connector version is also available where automated wiring facilities are available.
TLX5/1hr/E/T-Slim
Emergency Control Unit (Slim-Line)
VERSION BALLAST TYPES DURATION BATTERY PACK (Ni-cad) FLUORESCENT LAMPS
TLX3/1hr Switch start One hour 3 x 2 Ahr cells Up to 36 Watts
TLX5/1hr Switch start One hour 5 x 2 Ahr cells Up to 65 Watts
TLX5/1hr/E All One hour 5 x 2 Ahr cells Up to 80 Watts
TLX3/3hr/T Switch start Three hours 3 x 4 Ahr cells Up to 36 Watts
TLX5/3hr/T Switch start Three hours 5 x 4 Ahr cells Up to 65 Watts
TLX5/3hr/T/E All Three hours 5 x 4 Ahr cells Up to 80 Watts
SPECIFICATIONS: (parenthesis = 3 hour versions)
Mains voltage tolerance 230Vac +/- 10% 50 Hz
Lamp types 7  to 80 Watt fluorescent lamps
Emergency lighting duration (3 hours) 1 hour
Mains power consumption 2VA
Battery discharge current 1 A
Deep discharge protection > 0.8V/cell
Charging current (200 mA) 100 mA
Charging indication provided
Quiescent current < 1 µA
Battery short circuit tolerance indefinite
Dimensions:  
Controller:   171 x 45 x 35mm
Battery   3.6 – 6V ni-cad
Maximum operating temperature +70°C
The table below shows the performance of the units with various lamps (parenthesis = 3 hour units)
LAMP TYPE LIGHT OUTPUT BATTERY CURRENT DURATION
T12: 65W 65W 11% (9%) 1.3A (1A) 1.4 (4) hours
T8 : 58 58W 12% (11%) 1.3A (1A) 1.4 (4) hours
T12: 40 W 15% (13%) 1.2A (0.8A) 1.5 (4.7) hours
T8: 36W 36W 18% (15%) 1.1A (0.9A) 1.6 (4.4) hours
T12: 20W 19% (17%) 0.6A (0.6A) 3 (6.8) hours
T8: 18W 18W 20% (22%) 0.7A (0.7A) 2.6 (6.1) hours
T8: 10W 10W 30% (32%) 0.6A (0.5A) 3 (8) hours
T5: 8W 8W 40% (45%) 0.7A (0.6A) 2.6 (6.8) hours
TC-DEL: 26W 32% (18%) 1.2A (0.8A) 1.5 (4.7) hours
TC-DEL: 18W 29% (26%) 1A (0.8A) 1.8 (4.7) hours
TC-DEL: 13W 36% (30%) 1A (0.6A) 1.8 (6.8) hours
TC-DD: 28W 25% (15%) 1.2A (0.7A) 1.5 (6.1) hours
TC-L: 18W 23% (19%) 0.7A (0.6A) 2.6 (6.8) hours
TC-EL: 11W 43% (42%) 0.9A (0.6A) 2 (6.8) hours
TC-EL: 9W 36% (31%) 0.6A (0.5A) 3 (8) hours
TC-EL: 7W 38% (44%) 0.7A (0.5A) 2.6 (8) hours
Ø Slim-Line version of Standard TLX5/1hr/E/T Emergency Controller
Ø Designed specifically for T5 bulkheads
Ø Low profile housing i.e. W=30mm x H=30mm
Ø 1 hour Emergency light
Ø Low Battery discharge protection
Ø Reverse battery protection
Ø Maintained or non-maintained
Ø Drives 8 to 80W lamps i.e. linear and CFL’s
Ø Designed, developed and manufactured in South Africa
Ø Suitable for switch start and electronic ballasts
SPECIFICATIONS: (parenthesis = 3 hour versions)
Mains voltage tolerance 230Vac +/- 10% 50 Hz
Lamp types T5 - (8 > 80) Watt fluorescent lamps
Emergency lighting duration 1 hour
Mains power consumption 2VA
Battery discharge current 1 A
Deep discharge protection > 0.8V/cell
Charging current 100 mA
Charging indication provided
Quiescent current < 1 µA
Battery short circuit tolerance indefinite
Dimensions:  
Controller:   L=253 x W=32 x H=32mm
Battery   6v ni-cad
Maximum case temperature +70°C
Maximum operating temperature +(Ta)0°C to 50°C
24 Ashfield Avenue
Springfield Park
Durban, South Africa

Telephone: +27 31 579 2172
Fax: +27 31 579 2176

PO Box 10177
Marine Parade
4056, South Africa

E-mail:
admin@cosine.co.za Web: www.cosine.co.za
COSINE DEVELOPMENTS
Leaders in lighting technology